POLYBRON 708
ONE-COMPONENT SOLVENT BASED AROMATIC POLYURETHANE RESIN
DESIGNATION | POLYBRON 708 Supple liquid polyurethane waterproofing system for concrete Prepolymer reacting with air humidity. Semi-thick polyurethane elastomer. |
APPLICATION | Aromatic polyurethane resin for indoors and outdoors applications. To get a perfect colour stability outdoors, use aliphatic POLYBRON 707 resin. |
LOCALIZATION | POLYBRON 708 suits to all waterproofing works or
waterproofing repairs for :
|
SUBSTRATES | Old or new concrete substrates, indoors or outdoors if
UV protected. Concrete and cement structures, wood and wood aggregates Ferrous and non ferrous metals Old coatings : make sure of the perfect adhesion of the previous protection and its compatibility with the primer. |
PROPERTIES | One-component polyurethane resin ready to use, in
solution with an organic solvent allowing to obtain a waterproof coat. Supple and resistant polymerised film. |
SUBSTRATE PREPARATION | The substrates have to be perfectly clean, dry and free from grease. Any impurity or non adhesive part should be removed. Cohesion should be checked. Sharp angles must be pressed down. Avoid humidity traces. Substrate humidity should not exceed 6%. Please refer to the technical data sheet of the adhesion primer adapted to the substrate. |
APPLICATION | Manual application : Brush or roll without
dilution. Apply two crossed and regular coats. Interval time between two coats : minimum 12 hours and maximum 48 hours. The application must comply with DTU norms and Art rules. Refer to the Cahier des Clauses Techniques VERITAS CEMEX-POLYBRON N°9 of 12/93 Do not apply if hygrometry is >85%. Do not apply by rainy or cloudy conditions. Minimum temperature for application : 5°C. The surface temperature must always be 3°C over the dew point temperature, according to temperature and humidity, determined by relative humidity. If temperature is >35°C, specific arrangements must be made. |
EFFICIENCY |
|
PRECAUTIONS FOR USE |
|
TECHNICAL DATA |
|
SHELF LIFE | Shelter the closed packs in a dry, temperate and
ventilated place. Avoid frost and temperatures > 30°C. Maximum shelf life : 6 months. |
REGULATIONS |
|
Information and recommendations contained in this data sheet are the result of experience gained under controlled circumstances and today knowledge. Their accuracy and completeness under the actual conditions of any intended use are not guaranteed and must be determined by our approved applicators since application is beyond control. Disclaims and any liability in excess of what is stated therein for results obtained, injury, direct or indirect damages. Total or partial reproducing of this document can only be made with our express agreement.